platform event trap

Platform Event Trap PET Explained in Simple Words

A Platform Event Trap also called PET is a message that comes from the hardware inside a server or network device, it tells you when something important or dangerous is happening, PET alerts you before the operating system starts or even when the system is not working, this makes PET one of the best early warning tools in any data center Increditools

In this guide you will learn what PET is how it works why it matters and how to use it, everything is explained in basic words so anyone can understand it

What is a Platform Event Trap PET

A Platform Event Trap is a fast alert that is sent when a part inside the system detects a problem, the alert is sent using a protocol called SNMP, this protocol helps devices send messages to monitoring tools

PET warns you about events that happen at the hardware level, these events happen before the operating system loads or when the system is stuck, because of this PET gives you the earliest possible warning about a failure

Simple meaning of PET

PET is a message that warns you about hardware problems

PET works even when the operating system is down

PET helps you fix things before the server stops working

Why PET is important

It protects your servers from damage

It helps you avoid downtime

It warns you early so you can respond fast

Where PET Events Come From

PET events do not come from software, they come from the physical parts of the server, these parts always run even when the system is powered off, they watch for problems and send alerts when needed

Main sources of PET events

BIOS or UEFI firmware

The baseboard management controller also called BMC

Fans and temperature sensors

Power supplies

Voltage controllers

CPU and memory sensors

Chassis intrusion sensors

These parts make sure the system is safe at all times. When something looks wrong they send a PET message.

Table of Common PET Event Categories

This table shows the types of events that usually trigger PET alerts

Event Category What It Means
Thermal events The system is too hot or cooling is not working
Fan events A fan is slow or stopped
Power events Power supply failed or lost input power
Voltage events Voltage is too high or too low
CPU or memory events CPU or memory has errors
Chassis alerts Someone opened the case or tampered with the system
Boot errors BIOS reports a startup failure

These are the main reasons a PET alert happens, they help you see what part needs attention

How PET Works Step by Step

PET follows a simple and clear process, sensors watch the system, when they find a problem the BMC records it, then a PET message is sent to your monitoring tool

Simple steps of PET operation

A sensor detects a problem

The BMC stores the event in the event log

The event gets classified

A PET message is created

The message is sent to your monitoring system

This happens very fast, PET messages are sent without waiting for any reply so alerts never get slowed down

Table of PET Message Fields

A PET message contains several pieces of information, these help monitoring tools understand what happened

PET Field Purpose
Sensor type Shows which part triggered the event
Event type Explains the nature of the problem
Severity Tells if the issue is warning critical or severe
Event time Shows when the event happened
Event source Tells where the event started
Event data Contains details about the event
Vendor info Extra data added by the manufacturer

These fields help you know exactly what is going wrong and where

Real Examples of PET Events

Here are simple examples of situations that cause PET alerts

Thermal examples

CPU is too hot

Case temperature is too high

Cooling system not working

Fan examples

Fan is spinning too slow

Fan has stopped

Fan is missing

Power examples

Power supply failed

Power input lost

Redundant power not available

Voltage examples

High voltage detected

Low voltage detected

Voltage regulator failure

Security examples

Chassis opened

Intrusion switch triggered

Boot examples

BIOS error

Memory test failed

CPU failed to start

These events can damage systems if not handled early, PET helps you act before that happens

How to Configure PET

Configuring PET is easy when you follow the right steps, most systems use a BMC interface or a vendor management tool

Steps to enable PET

Turn on PET in the BMC menu

Set up the SNMP trap receiver address

Choose an SNMP community or SNMPv3 user

Adjust event filters

Test the PET output

Where you can configure PET

Server BMC web interface

BIOS or UEFI menu

Vendor tools like UCS Manager

Command line tools like IPMItool

What you must configure

PET on or off

SNMP destination server

Event filters

Security settings like SNMPv3

When finished PET will send alerts to your monitoring tool

PET in Monitoring Systems

PET is supported by many monitoring tools, these tools help you view alerts store them and create actions

Monitoring tools that support PET

SolarWinds

Zabbix

Nagios

PRTG

ManageEngine

DataDog with SNMP traps

Splunk with SNMP collector

What monitoring tools can do with PET

Show alerts instantly

Make dashboards

Create support tickets

Trigger automated fixes

Record events for history

Help find root causes

With PET you get alerts at the hardware level before the system fails

PET and Syslog Working Together

PET is fast and simple, syslog is detailed and provides history. Both are important

PET strengths

Sends alerts right away

Works without the operating system

Very light and fast

Syslog strengths

Stores complete event history

Contains detailed information

Helps with deep troubleshooting

Best practice

Use PET for fast warnings
Use syslog for deep analysis

Together they give complete visibility

Troubleshooting PET Problems

Sometimes PET does not behave as expected, here are simple solutions

PET not sending alerts

PET might be off

Wrong SNMP destination

SNMP service not enabled

Network firewall blocking port 162

Too many PET alerts

Sensor thresholds too low

Bad sensor

Filters not configured

Monitoring tool cannot read PET

Missing MIB files

Wrong parser rules

Vendor fields not recognized

Duplicate PET alerts

Multiple BMC controllers

Two sensors for one event

Fixing PET issues starts with checking the event log inside the BMC

PET and Security

PET can help with security too, it reports physical issues and strange hardware activity

Security risks if using SNMPv2c

Data is not encrypted

Attackers can read messages

Attackers can spoof alerts

Benefits of SNMPv3

Encryption

Authentication

User control

Safe communication

Security events PET can detect

Case opened

Power removed without reason

Hardware tampering

Abnormal temperature from hidden workloads

Using PET as part of a security plan strengthens physical protection

Best Practices for Using PET

Follow these simple guidelines

Always enable SNMPv3

Use more than one trap receiver

Update firmware often

Test PET alerts on a schedule

Avoid sending non critical alerts

Connect PET to ticketing tools

Match PET events with syslog events

Monitor PET history for patterns

These steps help you use PET in the most stable and safe way

Frequently Asked Questions

What is a Platform Event Trap?

A Platform Event Trap is a fast alert from the hardware that warns you when a part inside the server has a problem, it sends a message before the operating system starts so you get early warning of failures

Why is a Platform Event Trap important?

A Platform Event Trap helps you stop hardware damage and avoid downtime, it gives you early alerts so you can fix problems before the system stops working

How does a Platform Event Trap work?

The system has sensors that watch for problems, when they detect an issue the BMC records it and creates a Platform Event Trap, the message is then sent to your monitoring tool

What problems can a Platform Event Trap detect?

A Platform Event Trap can detect heat issues power loss fan failure voltage problems boot errors and even chassis intrusion

Can a Platform Event Trap work when the system is off?

Yes a Platform Event Trap works even when the operating system is down because it comes from the hardware and not from software

How do I set up a Platform Event Trap?

You turn it on inside the BMC, you set the SNMP trap destination, you adjust event filters, then you test the alert to make sure it works

Does a Platform Event Trap help with security?

Yes it can warn you when someone opens the case or tampers with the hardware, it also helps detect strange power or temperature activity

Which monitoring tools support Platform Event Trap?

Tools like Solar Winds Zabbix Nagios PRTG Manage Engine and Splunk can receive Platform Event Trap alerts through SNMP

What should I do if I get too many Platform Event Trap alerts?

You should check sensor settings and tune the event filters, some sensors may need repair, set filters only for important alerts

Does a Platform Event Trap need SNMPv3?

SNMPv3 is strongly recommended because it gives safe and encrypted communication, SNMPv2c is less secure

Conclusion

Platform Event Traps are one of the most powerful and reliable tools for detecting hardware problems early, they work even when the operating system is not working, they alert you about the most serious issues like heat problems fan failures power issues and physical tampering, PET gives you time to act before damage happens